The common faults that magnetic polishing machine may encounter include water leakage, equipment malfunction, and excessive vibration. How to maintain the magnetic polishing machine if it malfunctions? We need to analyze the specific problems of magnetic polishing machines.
1.Water leakage is usually caused by a missing polishing bucket. Although our polishing buckets are very durable, we have also seen cases where customers use them improperly, resulting in severe wear and tear.
In general, when facing this situation, if the wear is too severe, we recommend replacing it. If the leakage is caused by the polishing needle piercing through, we can use a bottom spike and pliers to remove the polishing needle with a perforated bottom, and add some glue.
2.If the indication is normal but the machine is not working, we can check if the connection voltage of the polishing machine is very low (below 200V); Timely adjustment of power supply.
3.If there is significant machine vibration, check if each corner of the machine’s foot is in the position of force. Confirm that there are no problems before checking if there are too many polishing parts inserted.
The above is the relevant content of Guangu magnetic polishing machine, hoping to be helpful to everyone. Everyone can choose the appropriate deburring and polishing equipment according to their own needs.